Memmert ICO240 K7 CO2 Incubator w/ Active Humidity Control 241L, 115V
Temperature Range Ambient +5°C to 50°C
Humidity Control
40 to 97% RH, or no RH
Chamber Volume 241L (8.5 cu. ft.)
- Expert precision and control for optimal protection of cultures
- User-friendly, intuitive operating concept for ease of use
- Allows for direct humidity control from 40 to 97% RH, or no RH
- High-quality, corrosion-resistant stainless steel construction for durability and cleanliness
- Easily cleanable inner chamber and housing
- Rapid heating to setpoint without overshoots for consistent results
- Rounded interior edges for simplified, thorough cleaning
- Interior sterilization possible at 180°C for 60 minutes without removing sensors
- Integrated data logger and adjustable digital timer from 1 minute to 99 days
- AtmoCONTROL software for programming, data logging, and device monitoring
- SetpointWAIT function ensures process timing starts only when set temperature is reached
- Alarm notifications to mobile devices for enhanced safety and monitoring
- Battery-buffered ControlCOCKPIT ensures continuous CO2 control even during power outages
The Memmert ICO240 K7 CO2 Incubator w/ Active Humidity Control 241L, 115V offers unparalleled precision and control for demanding laboratory applications, ensuring optimal protection for cell cultures, bacteria cultures, and tissue cultures. Designed with user-friendliness in mind, it features an intuitive operating system complemented by a high-quality stainless steel inner chamber and housing that are both corrosion-resistant and easy to clean. This incubator excels in maintaining a hygienic environment with its rounded interior edges and the ability to sterilize the interior at 180°C for 60 minutes without removing sensors, promoting effortless cleaning and maintenance.
Equipped with an advanced control system, the ICO240 K7 reaches desired temperatures swiftly without overshoots, and it includes a battery-buffered ControlCOCKPIT for continuous CO2 control, even during power outages. Alarm notifications can be sent directly to your mobile device, ensuring the safety and integrity of the chamber's contents. The incubator comes with an integrated data logger and a digital timer that can be set from 1 minute to 99 days and 23 hours, supporting complex ramping processes and precise temperature control. With the K7 active humidity option installed, this CO2 Incubator allows for direct humidity control from 40 to 97% RH, or no RH.
Further enhancing its functionality, the ICO240 K7 features the AtmoCONTROL software for easy programming and online monitoring of up to 32 connected devices. The software enables simple drag-and-drop input of values and can send automatic alarm messages to multiple email addresses. The SetpointWAIT function ensures that process times start only when the target temperature is reached at all monitoring points. With its robust construction and high-end safety features, the Memmert ICO240 K7 CO2 Incubator is an indispensable tool for any research facility focused on cell and tissue culture.
The
Memmert ICO240 K7 CO2 Incubator w/ Active Humidity Control 241L, 115V includes:
- 2 x Stainless Steel Perforated Shelves
- Water Tank
- Gas Connection Hose
- 2 x Silicone Plugs
- USB Drive w/ Software & AtmoCONTROL Manual
- Calibration Certificate
- Power Cord
- Operator's Manual
- Manufacturer's Documentation
- 3 Year Manufacturer's Warranty
Memmert ICO240 K7 CO2 Incubator w/ Active Humidity Control 241L, 115V Specifications
Temperature Range
|
Ambient +5°C to 50°C
|
Temperature Uniformity
|
± 0.3°C at 37°C
|
Volume
|
241L (8.5 cu. ft.)
|
CO2 Range
|
0 to 20%
|
Sterilization Program
|
60 minutes at 180°C (without removing the sensors)
|
Temperature Setting Resolution
|
0.1°C
|
Temperature Stability
|
± 0.1°C
|
Temperature Sensor
|
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
|
Active Humidity Control
|
40 to 97% RH, or no RH
|
CO2 Control
|
Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation
|
CO2 Setting Accuracy
|
0.1%
|
CO2 Stability
|
± 0.2%
|
Control Technology
|
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
|
Language Setting
|
German, English, Spanish, French, Polish, Czech, Hungarian
|
Function SetpointWAIT
|
The process time does not start until the set temperature is reached
|
Adjustable Parameters
|
Temperature (Celsius or Fahrenheit), CO2, Timer
|
Communication Interfaces
|
Ethernet LAN, USB
|
Documentation Program
|
Stored in case of power failure
|
Programming
|
AtmoCONTROL software on a USB stick for programming, managing and transferring programs via Ethernet interface or USB port
|
AutoSAFETY
|
Additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
|
Autodiagnostic System
|
Integral fault diagnostics for temperature and CO2
|
Alarm
|
Visual and acoustic
|
Heating Concept
|
6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation
|
Door
|
Fully insulated stainless steel door with 2-point locking (compression door lock)
|
Shelving
|
2 perforated stainless steel shelves
|
Inner Glass Door
|
with opening (8 mm Ø) to take gas sample
|
Interior Material
|
1.4301 (ASTM 304), corrosion resistant
|
Max. Number of Shelves
|
12
|
Max. Loading of Chamber
|
308 lb. (139.7 kg)
|
Max. Loading per Shelf
|
33 lb. (15 kg)
|
Housing rear
|
Zinc-plated steel
|
Country of origin
|
Germany
|
Internal Dimensions (W x H x D
|
23.6 x 31.9 x 19.7 in. (59.9 x 81 x 50 cm)
|
External Dimensions (W x H x D)
|
29.9 x 46.5 x 27.2 in. (75.9 x 118.1 x 69.1 cm)
|
Weight
|
243 lb. (110.2 kg)
|
Electrical Requirements
|
115 V (±10%), 50/60 Hz approx. 1650 W / 14.4 A
|
Spec / Product
|
Memmert ICO50 CO2 Incubator 56L, 115V
|
Memmert ICO105 CO2 Incubator 107L, 115V
|
Memmert ICO150 CO2 Incubator 156L, 115V
|
Memmert ICO240 CO2 Incubator 241L, 115V
|
Memmert ICO50 K7 CO2 Incubator w/ Active Humidity Control 56L, 115V
|
Memmert ICO105 K7 CO2 Incubator w/ Active Humidity Control 107L, 115V
|
Memmert ICO150 K7 CO2 Incubator w/ Active Humidity Control 156L, 115V
|
Memmert ICO240 K7 CO2 Incubator w/ Active Humidity Control 241L, 115V
|
Temperature Range
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Ambient +5°C to 50°C
|
Temperature Uniformity
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
± 0.3°C at 37°C
|
Volume
|
56L (2 cu. ft.)
|
107L (3.8 cu. ft.)
|
156L (5.5 cu. ft.)
|
241L (8.5 cu. ft.)
|
56L (2 cu. ft.)
|
107L (3.8 cu. ft.)
|
156L (5.5 cu. ft.)
|
241L (8.5 cu. ft.)
|
CO2 Setting Accuracy
|
0.10%
|
0.10%
|
0.10%
|
0.10%
|
0.10%
|
0.10%
|
0.10%
|
0.10%
|
Active Humidity Control
|
N.A
|
N.A
|
N.A
|
N.A
|
40 to 97% RH, or no RH
|
40 to 97% RH, or no RH
|
40 to 97% RH, or no RH
|
40 to 97% RH, or no RH
|
Max. Number of Shelves
|
5
|
6
|
10
|
12
|
5
|
6
|
10
|
12
|
Max. Loading of Chamber
|
165 lb. (74.9 kg)
|
198 lb. (89.8 kg)
|
264 lb. (119.7 kg)
|
308 lb. (139.7 kg)
|
165 lb. (74.9 kg)
|
198 lb. (89.8 kg)
|
264 lb. (119.7 kg)
|
308 lb. (139.7 kg)
|
Internal Dimensions (W x H x D)
|
15.7 x 16.7 x 13 in. (39.9 x 42.4 x 33 cm)
|
22 x 18.9 x 15.7 in. (55.9 x 48 x 39.9 cm)
|
22 x 27.6 x 15.7 in. (55.9 x 70.1 x 39.9 cm)
|
23.6 x 31.9 x 19.7 in. (59.9 x 81 x 50 cm)
|
15.7 x 16.7 x 13 in. (39.9 x 42.4 x 33 cm)
|
22 x 18.9 x 15.7 in. (55.9 x 48 x 39.9 cm)
|
22 x 27.6 x 15.7 in. (55.9 x 70.1 x 39.9 cm)
|
23.6 x 31.9 x 19.7 in. (59.9 x 81 x 50 cm)
|
Electrical Requirements
|
115 V (±10%), 50/60 Hz approx. 1100 W / 9.6 A
|
115 V (±10%), 50/60 Hz approx. 1300 W / 11.4 A
|
115 V (±10%), 50/60 Hz approx. 1500 W / 13.1 A
|
115 V (±10%), 50/60 Hz approx. 1650 W / 14.4 A
|
115 V (±10%), 50/60 Hz approx. 1100 W / 9.6 A
|
115 V (±10%), 50/60 Hz approx. 1300 W / 11.4 A
|
115 V (±10%), 50/60 Hz approx. 1500 W / 13.1 A
|
115 V (±10%), 50/60 Hz approx. 1650 W / 14.4 A
|
|
|
|
|
|
|
|