Home > Brands > A&D Weighing
Sort By:
Page of 2
A&D Weighing ION BM-252 Semi-Micro Analytical Balance, 250 g, 0.01 mg A&D Weighing ION BM-252 Semi-Micro Analytical Balance, 250 g, 0.01 mg

Capacity 250 g
Readability 0.01 mg
Repeatability (S.D.) 0.03 mg (for 100 g)
Linearity ± 0.010 mg
Minimum Weight (Typical) 20 mg
Stabilization Time (Set to FAST) ~8 sec
Sensitivity Drift ± 2 ppm / °C ( When automatic self calibration is not used )
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units g, mg, oz, ozt, ct, momme, dwt, GN, tael*4, tola*4, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 in. (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $6,350.00
Our Price: $5,715.00
Money Saved: $635.00
Free Shipping
A&D Weighing ION BM-300 Analytical Balance, 320 g, 0.1 mg A&D Weighing ION BM-300 Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.1 mg
Repeatability (S.D.) 0.2 mg
Linearity ± 0.3 mg
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) ~ 3.5 sec
Sensitivity Drift ± 2 ppm / °C (When automatic self calibration is not used)
Operating Temperature 5 °C to 40 °C (41 °F to 104 °F), 85% RH or less (non-condensation)
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units (Display Mode) g, mg, oz, ozt, ct, momme, dwt, GN, tael, tola, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 300, 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 inches (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $5,200.00
Our Price: $4,680.00
Money Saved: $520.00
Free Shipping
A&D Weighing ION BM-500 Analytical Balance, 520 g, 0.1 mg A&D Weighing ION BM-500 Analytical Balance, 520 g, 0.1 mg

Capacity 520 g
Readability 0.1 mg
Repeatability (S.D.) 0.2 mg
Linearity ± 0.5 mg
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) ~ 3.5 sec
Sensitivity Drift ± 2 ppm / °C (When automatic self calibration is not used)
Operating Temperature 5 °C to 40 °C (41 °F to 104 °F), 85% RH or less (non-condensation)
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units (Display Mode) g, mg, oz, ozt, ct, momme, dwt, GN, tael, tola, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 500, 300, 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 inches (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $6,150.00
Our Price: $5,535.00
Money Saved: $615.00
Free Shipping
A&D Weighing Apollo GX-124AE Analytical Balance, 120 g, 0.1 mg A&D Weighing Apollo GX-124AE Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,575.00
Our Price: $3,660.00
Money Saved: $915.00
Free Shipping
A&D Weighing Apollo GX-124AEN Analytical Balance, 120 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-124AEN Analytical Balance, 120 g, 0.1 mg (NTEP Class I)

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
NTEP Certification Class I
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,780.00
Our Price: $3,824.00
Money Saved: $956.00
Free Shipping
A&D Weighing Apollo GX-224AE Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GX-224AE Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ±0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec
Sensitivity Drift ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Internal Memory Not specified
External Data Logger Not specified
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal/external calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,770.00
Our Price: $3,816.00
Money Saved: $954.00
Free Shipping
A&D Weighing Apollo GX-224AEN Analytical Balance, 220 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-224AEN Analytical Balance, 220 g, 0.1 mg (NTEP Class I)

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ±0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec
Sensitivity Drift ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal/external calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,980.00
Our Price: $3,984.00
Money Saved: $996.00
Free Shipping
A&D Weighing Apollo GX-324AE Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GX-324AE Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Internal Memory Not specified
External Data Logger Not specified
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $5,125.00
Our Price: $4,100.00
Money Saved: $1,025.00
Free Shipping
A&D Weighing Apollo GX-324AEN Analytical Balance, 320 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-324AEN Analytical Balance, 320 g, 0.1 mg (NTEP Class I)

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times / second, 10 times / second or 20 times / second
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $5,330.00
Our Price: $4,264.00
Money Saved: $1,066.00
Free Shipping
A&D Weighing Apollo GX-124A Analytical Balance, 120 g, 0.1 mg A&D Weighing Apollo GX-124A Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,160.00
Our Price: $2,528.00
Money Saved: $632.00
Free Shipping
A&D Weighing Apollo GX-224A Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GX-224A Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g (200 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (200 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,510.00
Our Price: $2,808.00
Money Saved: $702.00
Free Shipping
A&D Weighing Apollo GX-324A Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GX-324A Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,920.00
Our Price: $3,136.00
Money Saved: $784.00
Free Shipping
A&D Weighing Apollo GX-124AN Analytical Balance, 120 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-124AN Analytical Balance, 120 g, 0.1 mg (NTEP Class I)

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1% or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,365.00
Our Price: $2,692.00
Money Saved: $673.00
Free Shipping
A&D Weighing Apollo GX-224AN Analytical Balance, 220 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-224AN Analytical Balance, 220 g, 0.1 mg (NTEP Class I)

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 2 sec (200 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,720.00
Our Price: $2,976.00
Money Saved: $744.00
Free Shipping
A&D Weighing Apollo GX-324AN Analytical Balance, 320 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-324AN Analytical Balance, 320 g, 0.1 mg (NTEP Class I)

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,125.00
Our Price: $3,300.00
Money Saved: $825.00
Free Shipping
A&D Weighing Apollo GF-124A Analytical Balance, 122 g, 0.1 mg A&D Weighing Apollo GF-124A Analytical Balance, 122 g, 0.1 mg

Capacity 122 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,705.00
Our Price: $2,164.00
Money Saved: $541.00
Free Shipping
A&D Weighing Apollo GF-224A Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GF-224A Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g (200 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,045.00
Our Price: $2,436.00
Money Saved: $609.00
Free Shipping
A&D Weighing Apollo GF-324A Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GF-324A Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g, 200 g, 300 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,600.00
Our Price: $2,880.00
Money Saved: $720.00
Free Shipping
A&D Weighing Galaxy HR-100AZ Analytical Balance, 102 g, 0.1 mg A&D Weighing Galaxy HR-100AZ Analytical Balance, 102 g, 0.1 mg

Capacity 102 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Minimum Weighing Value 0.1 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,485.00
Our Price: $1,863.75
Money Saved: $621.25
Free Shipping
A&D Weighing Galaxy HR-150AZ Analytical Balance, 152 g, 0.1 mg A&D Weighing Galaxy HR-150AZ Analytical Balance, 152 g, 0.1 mg

Capacity 152 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 150 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,715.00
Our Price: $2,036.25
Money Saved: $678.75
Free Shipping
A&D Weighing Galaxy HR-250AZ Analytical Balance, 252 g, 0.1 mg A&D Weighing Galaxy HR-250AZ Analytical Balance, 252 g, 0.1 mg

Capacity 252 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg, 200 to 252 g: 0.2 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 250 g, 200 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,880.00
Our Price: $2,160.00
Money Saved: $720.00
Free Shipping
A&D Weighing Galaxy HR-100A Analytical Balance, 102 g, 0.1 mg A&D Weighing Galaxy HR-100A Analytical Balance, 102 g, 0.1 mg

Capacity 102 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Minimum Weighing Value 0.1 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $1,995.00
Our Price: $1,496.25
Money Saved: $498.75
Free Shipping
A&D Weighing Galaxy HR-150A Analytical Balance, 152 g, 0.1 mg A&D Weighing Galaxy HR-150A Analytical Balance, 152 g, 0.1 mg

Capacity 152 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 150 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,220.00
Our Price: $1,665.00
Money Saved: $555.00
Free Shipping
A&D Weighing Galaxy HR-250A Analytical Balance, 252 g, 0.1 mg A&D Weighing Galaxy HR-250A Analytical Balance, 252 g, 0.1 mg

Capacity 252 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg, 200 to 252 g: 0.2 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 250 g, 200 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,425.00
Our Price: $1,818.75
Money Saved: $606.25
Free Shipping
A&D Weighing Phoenix GH-120 Analytical Balance, 120 g, 0.1 mg A&D Weighing Phoenix GH-120 Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 50 g, 100 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,185.00
Our Price: $3,348.00
Money Saved: $837.00
Free Shipping
A&D Weighing Phoenix GH-200 Analytical Balance, 220 g, 0.1 mg A&D Weighing Phoenix GH-200 Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,740.00
Our Price: $3,792.00
Money Saved: $948.00
Free Shipping
A&D Weighing Phoenix GH-300 Analytical Balance, 320 g, 0.1 mg A&D Weighing Phoenix GH-300 Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.2 mg
Linearity ± 0.3 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g, 300 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $5,575.00
Our Price: $4,460.00
Money Saved: $1,115.00
Free Shipping
A&D Weighing Gemini GR-120 Analytical Balance, 120 g, 0.1 mg A&D Weighing Gemini GR-120 Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 sec (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 50 g, 100 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $3,535.00
Our Price: $2,651.25
Money Saved: $883.75
Free Shipping
A&D Weighing Gemini GR-200 Analytical Balance, 210 g, 0.1 mg A&D Weighing Gemini GR-200 Analytical Balance, 210 g, 0.1 mg

Capacity 210 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 9.8 x 12.99 x 12.87 inches (249 x 330 x 327 mm)
Breeze Break Dimensions (W x D x H) 7.01 x 6.5 x 9.17 inches (178 x 160 x 233 mm)
Weight Approx. 13.2 lb (6.0 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,010.00
Our Price: $3,007.50
Money Saved: $1,002.50
Free Shipping
A&D Weighing Gemini GR-300 Analytical Balance, 310 g, 0.1 mg A&D Weighing Gemini GR-300 Analytical Balance, 310 g, 0.1 mg

Capacity 310 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 200 g, 300 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 9.8 x 12.99 x 12.87 inches (249 x 330 x 327 mm)
Breeze Break Dimensions (W x D x H) 7.01 x 6.5 x 9.17 inches (178 x 160 x 233 mm)
Weight Approx. 13.2 lb (6.0 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $4,995.00
Our Price: $3,746.25
Money Saved: $1,248.75
Free Shipping