A&D Weighing ION BM-252 Semi-Micro Analytical Balance, 250 g, 0.01 mg A&D Weighing ION BM-252 Semi-Micro Analytical Balance, 250 g, 0.01 mg

Capacity 250 g
Readability 0.01 mg
Repeatability (S.D.) 0.03 mg (for 100 g)
Linearity ± 0.010 mg
Minimum Weight (Typical) 20 mg
Stabilization Time (Set to FAST) ~8 sec
Sensitivity Drift ± 2 ppm / °C ( When automatic self calibration is not used )
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units g, mg, oz, ozt, ct, momme, dwt, GN, tael*4, tola*4, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 in. (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Manufacturer's List Price: $6,350.00
Our Price: $5,715.00
Money Saved: $635.00
Free Shipping
A&D Weighing ION BM-300 Analytical Balance, 320 g, 0.1 mg A&D Weighing ION BM-300 Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.1 mg
Repeatability (S.D.) 0.2 mg
Linearity ± 0.3 mg
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) ~ 3.5 sec
Sensitivity Drift ± 2 ppm / °C (When automatic self calibration is not used)
Operating Temperature 5 °C to 40 °C (41 °F to 104 °F), 85% RH or less (non-condensation)
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units (Display Mode) g, mg, oz, ozt, ct, momme, dwt, GN, tael, tola, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 300, 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 inches (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Manufacturer's List Price: $5,200.00
Our Price: $4,680.00
Money Saved: $520.00
Free Shipping
A&D Weighing ION BM-500 Analytical Balance, 520 g, 0.1 mg A&D Weighing ION BM-500 Analytical Balance, 520 g, 0.1 mg

Capacity 520 g
Readability 0.1 mg
Repeatability (S.D.) 0.2 mg
Linearity ± 0.5 mg
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) ~ 3.5 sec
Sensitivity Drift ± 2 ppm / °C (When automatic self calibration is not used)
Operating Temperature 5 °C to 40 °C (41 °F to 104 °F), 85% RH or less (non-condensation)
Display Refresh Rate 5 times / sec or 10 times / sec
Measurement Units (Display Mode) g, mg, oz, ozt, ct, momme, dwt, GN, tael, tola, messghal, pieces (counting mode), % (percent mode), Specific gravity
Counting Mode Minimum unit mass = 0.1 mg / Number of samples = 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% ref. mass = 10.0 mg / Minimum 100% display = 0.01%, 0.1%, 1% (depends on the reference mass stored)
Internal Memory 200 sets weighing data / 100 sets with date & time / 50 sets of calibration data
External Data Logger Store up to 5,000 weighing results with date & time to AD-1688 (standard)
Data Output GLP / GMP / GCP / ISO compliant. Outputs: balance manufacturer, model, s/n, balance identification number, data, time of calibration, mass used, and space for signature.
Standard Interface RS-232C, Quick USB, External key plug for optional foot switch (SW:128)
Internal Calibration Motor-driven internal calibration
External Calibration Masses (g) 500, 300, 200, 100, 50
Ionizer Electrode Pin Life ~10,000 hours of continuous use. (User replaceable)
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 18.3 x 12.8 inches (259 x 466 x 326 mm)
Weight 22 lb. (10 kg)
Electrical Requirements ~30 VA (supplied by the AC adapter)

Manufacturer's List Price: $6,150.00
Our Price: $5,535.00
Money Saved: $615.00
Free Shipping
A&D Weighing Apollo GX-124AE Analytical Balance, 120 g, 0.1 mg A&D Weighing Apollo GX-124AE Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $4,575.00
Our Price: $3,660.00
Money Saved: $915.00
Free Shipping
A&D Weighing Apollo GX-124AEN Analytical Balance, 120 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-124AEN Analytical Balance, 120 g, 0.1 mg (NTEP Class I)

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
NTEP Certification Class I
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter 90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $4,780.00
Our Price: $3,824.00
Money Saved: $956.00
Free Shipping
A&D Weighing Apollo GX-224AE Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GX-224AE Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ±0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec
Sensitivity Drift ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Internal Memory Not specified
External Data Logger Not specified
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal/external calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $4,770.00
Our Price: $3,816.00
Money Saved: $954.00
Free Shipping
A&D Weighing Apollo GX-224AEN Analytical Balance, 220 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-224AEN Analytical Balance, 220 g, 0.1 mg (NTEP Class I)

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ±0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec
Sensitivity Drift ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal/external calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $4,980.00
Our Price: $3,984.00
Money Saved: $996.00
Free Shipping
A&D Weighing Apollo GX-324AE Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GX-324AE Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5, 10, or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Internal Memory Not specified
External Data Logger Not specified
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $5,125.00
Our Price: $4,100.00
Money Saved: $1,025.00
Free Shipping
A&D Weighing Apollo GX-324AEN Analytical Balance, 320 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-324AEN Analytical Balance, 320 g, 0.1 mg (NTEP Class I)

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times / second, 10 times / second or 20 times / second
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting), %, SG (density), user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g; Sample sizes: 5, 10, 25, 50, 100 pieces
Percent Mode Minimum reference mass: 0.0100 g; % readability: 0.01%, 0.1%, or 1% (depends on reference mass)
Data Output Real-time output to connected devices
Standard Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 in. (259 x 358 x 332 mm) including large glass breeze break
Weight 15.4 lb (7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $5,330.00
Our Price: $4,264.00
Money Saved: $1,066.00
Free Shipping
A&D Weighing Apollo GX-124A Analytical Balance, 120 g, 0.1 mg A&D Weighing Apollo GX-124A Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration Internal
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,160.00
Our Price: $2,528.00
Money Saved: $632.00
Free Shipping
A&D Weighing Apollo GX-224A Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GX-224A Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g (200 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (200 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,510.00
Our Price: $2,808.00
Money Saved: $702.00
Free Shipping
A&D Weighing Apollo GX-324A Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GX-324A Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,920.00
Our Price: $3,136.00
Money Saved: $784.00
Free Shipping
A&D Weighing Apollo GX-124AN Analytical Balance, 120 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-124AN Analytical Balance, 120 g, 0.1 mg (NTEP Class I)

Capacity 120 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 1.5 sec (100 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1% or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,365.00
Our Price: $2,692.00
Money Saved: $673.00
Free Shipping
A&D Weighing Apollo GX-224AN Analytical Balance, 220 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-224AN Analytical Balance, 220 g, 0.1 mg (NTEP Class I)

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 2 sec (200 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,720.00
Our Price: $2,976.00
Money Saved: $744.00
Free Shipping
A&D Weighing Apollo GX-324AN Analytical Balance, 320 g, 0.1 mg (NTEP Class I) A&D Weighing Apollo GX-324AN Analytical Balance, 320 g, 0.1 mg (NTEP Class I)

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Stabilization Time (Set to FAST) Approx. 2 sec (300 g)
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
NTEP Certification Class I
Operating Temperature 10 to 30 °C | 50 to 86 °F, 85% R.H. or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50, or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Communication Interface RS-232C and USB
Internal Calibration Automatic self-calibration and one-touch internal calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $4,125.00
Our Price: $3,300.00
Money Saved: $825.00
Free Shipping
A&D Weighing Apollo GF-124A Analytical Balance, 122 g, 0.1 mg A&D Weighing Apollo GF-124A Analytical Balance, 122 g, 0.1 mg

Capacity 122 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g
Linearity ± 0.0002 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $2,705.00
Our Price: $2,164.00
Money Saved: $541.00
Free Shipping
A&D Weighing Apollo GF-224A Analytical Balance, 220 g, 0.1 mg A&D Weighing Apollo GF-224A Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.0001 g
Repeatability (S.D.) 0.0001 g (200 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass 0.0001 g
Number of samples 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass 0.0100 g
% readability 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g, 200 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,045.00
Our Price: $2,436.00
Money Saved: $609.00
Free Shipping
A&D Weighing Apollo GF-324A Analytical Balance, 320 g, 0.1 mg A&D Weighing Apollo GF-324A Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.0001 g
Repeatability (S.D.) 0.0002 g (300 g)
Linearity ± 0.0003 g
Minimum Weight (Typical) 120 mg
Stabilization Time (Set to FAST) Approx. 1 sec
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF)
Operating Temperature 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation)
Display Refresh Rate 5 times/sec, 10 times/sec or 20 times/sec
Measurement Units (Display Mode) mg, g, oz, ozt, ct, mom, dwt, gr, pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit
Counting Mode Minimum unit mass: 0.0001 g
Number of samples: 5, 10, 25, 50 or 100 pieces
Percent Mode Minimum 100% reference mass: 0.0100 g
% readability: 0.01%, 0.1% or 1% (depends on the reference mass stored)
Communication Interface RS-232C and USB
Calibration External Calibration
External Calibration Masses (g) 50 g, 100 g, 200 g, 300 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 10.2 x 14.1 x 13.1 inches (259 x 358 x 332 mm)
Weight 15.4 lb. (Approx. 7 kg)
Electrical Requirements AC adapter / approx. 30 VA

Manufacturer's List Price: $3,600.00
Our Price: $2,880.00
Money Saved: $720.00
Free Shipping
A&D Weighing Galaxy HR-100AZ Analytical Balance, 102 g, 0.1 mg A&D Weighing Galaxy HR-100AZ Analytical Balance, 102 g, 0.1 mg

Capacity 102 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Minimum Weighing Value 0.1 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $2,485.00
Our Price: $1,863.75
Money Saved: $621.25
Free Shipping
A&D Weighing Galaxy HR-150AZ Analytical Balance, 152 g, 0.1 mg A&D Weighing Galaxy HR-150AZ Analytical Balance, 152 g, 0.1 mg

Capacity 152 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 150 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $2,715.00
Our Price: $2,036.25
Money Saved: $678.75
Free Shipping
A&D Weighing Galaxy HR-250AZ Analytical Balance, 252 g, 0.1 mg A&D Weighing Galaxy HR-250AZ Analytical Balance, 252 g, 0.1 mg

Capacity 252 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg, 200 to 252 g: 0.2 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration Internal
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 250 g, 200 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 8.9 lb (3.9 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $2,880.00
Our Price: $2,160.00
Money Saved: $720.00
Free Shipping
A&D Weighing Galaxy HR-100A Analytical Balance, 102 g, 0.1 mg A&D Weighing Galaxy HR-100A Analytical Balance, 102 g, 0.1 mg

Capacity 102 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Minimum Weighing Value 0.1 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $1,995.00
Our Price: $1,496.25
Money Saved: $498.75
Free Shipping
A&D Weighing Galaxy HR-150A Analytical Balance, 152 g, 0.1 mg A&D Weighing Galaxy HR-150A Analytical Balance, 152 g, 0.1 mg

Capacity 152 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 150 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $2,220.00
Our Price: $1,665.00
Money Saved: $555.00
Free Shipping
A&D Weighing Galaxy HR-250A Analytical Balance, 252 g, 0.1 mg A&D Weighing Galaxy HR-250A Analytical Balance, 252 g, 0.1 mg

Capacity 252 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0 to 200 g: 0.1 mg, 200 to 252 g: 0.2 mg
Linearity ± 0.3 mg
Stabilization Time (Set to FAST) Approx. 2 seconds
Sensitivity Drift ± 2 ppm/°C (10 to 30 °C/50 to 86 °F)
Calibration External
Operating Environment 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second, selectable
Measurement Units (Display Mode) g, mg, oz, oz-t, ct, momme, dwt, grain, tael, tola, pieces (counting mode), % (percent mode), DS (density mode), user-definable functions
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Min. reference mass: 10.0 mg
Min. 100% Display: 0.01%, 0.1%, or 1% (depends on the reference mass stored)
Communication Interface RS-232C
Applicable Calibration Weight Values (g) 250 g, 200 g, 100 g, 50 g
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8 x 12 x 12.4 in (198 x 294 x 315 mm)
Weight 7.8 lb (3.5 kg)
Power Supply AC adapter
Power Consumption Approx. 11 VA (supplied by the AC adapter)

Manufacturer's List Price: $2,425.00
Our Price: $1,818.75
Money Saved: $606.25
Free Shipping
A&D Weighing Phoenix GH-120 Analytical Balance, 120 g, 0.1 mg A&D Weighing Phoenix GH-120 Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 50 g, 100 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $4,185.00
Our Price: $3,348.00
Money Saved: $837.00
Free Shipping
A&D Weighing Phoenix GH-200 Analytical Balance, 220 g, 0.1 mg A&D Weighing Phoenix GH-200 Analytical Balance, 220 g, 0.1 mg

Capacity 220 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $4,740.00
Our Price: $3,792.00
Money Saved: $948.00
Free Shipping
A&D Weighing Phoenix GH-300 Analytical Balance, 320 g, 0.1 mg A&D Weighing Phoenix GH-300 Analytical Balance, 320 g, 0.1 mg

Capacity 320 g
Readability 0.1 mg
Repeatability (Standard Deviation) 0.2 mg
Linearity ± 0.3 mg
Stabilization Time Approx. 3.5 seconds (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g, 300 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø90 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $5,575.00
Our Price: $4,460.00
Money Saved: $1,115.00
Free Shipping
A&D Weighing Gemini GR-120 Analytical Balance, 120 g, 0.1 mg A&D Weighing Gemini GR-120 Analytical Balance, 120 g, 0.1 mg

Capacity 120 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 sec (0.1 mg)
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 50 g, 100 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 8.54 x 17.4 x 12.24 inches (217 x 442 x 316 mm)
Breeze Break Dimensions (W x D x H) 7.2 x 5.84 x 9.88 inches (183 x 148.5 x 251 mm)
Weight 18 lb. (Approx. 8.2 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $3,535.00
Our Price: $2,651.25
Money Saved: $883.75
Free Shipping
A&D Weighing Gemini GR-200 Analytical Balance, 210 g, 0.1 mg A&D Weighing Gemini GR-200 Analytical Balance, 210 g, 0.1 mg

Capacity 210 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 100 g, 200 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 9.8 x 12.99 x 12.87 inches (249 x 330 x 327 mm)
Breeze Break Dimensions (W x D x H) 7.01 x 6.5 x 9.17 inches (178 x 160 x 233 mm)
Weight Approx. 13.2 lb (6.0 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $4,010.00
Our Price: $3,007.50
Money Saved: $1,002.50
Free Shipping
A&D Weighing Gemini GR-300 Analytical Balance, 310 g, 0.1 mg A&D Weighing Gemini GR-300 Analytical Balance, 310 g, 0.1 mg

Capacity 310 g
Readability 0.1 mg
Repeatability 0.1 mg
Linearity ± 0.2 mg
Stabilization Time Approx. 3.5 seconds
Sensitivity Drift ± 2 ppm/°C (10°C – 30°C)
Calibration Internal
External Calibration Mass (Optional) 200 g, 300 g
Operating Temperature 5°C to 40°C (41°F to 104°F), 85% RH or less (no condensation)
Display Refresh Rate 5 times/second or 10 times/second
Measurement Units (Display Mode) g, mg, oz, ozt, ct, mom, dwt, grain, tael, tola, pieces (counting mode), % (percent mode)
Counting Mode Minimum unit mass: 0.1 mg
Number of Samples: 10, 25, 50, or 100 Pieces
Percent Mode Minimum 100% reference mass: 10.0 mg
% readability: 0.01%, 0.1%, or 1% (depends on reference mass stored)
Weighing Pan Diameter Ø85 mm
Dimensions (W x D x H) 9.8 x 12.99 x 12.87 inches (249 x 330 x 327 mm)
Breeze Break Dimensions (W x D x H) 7.01 x 6.5 x 9.17 inches (178 x 160 x 233 mm)
Weight Approx. 13.2 lb (6.0 kg)
Power Supply 100, 120, 220, 240 VAC (AC Adapter) 50 Hz / 60 Hz, 11 VA

Manufacturer's List Price: $4,995.00
Our Price: $3,746.25
Money Saved: $1,248.75
Free Shipping