Home > Vacuum Pump Type > Helium Leak Detector
Sort By:
Page of 1
Edwards ELD500 - 100-120V 60Hz US Helium Leak Detector Edwards ELD500 - 100-120V 60Hz US Helium Leak Detector

Lowest Detectable Helium Leak Rate Vacuum Operation <5x10 -12 mbar
Lowest Detectable Helium Leak Rate Sniffer Operation ≤ 7 x 10 -9 mbar ls-1
Helium Pumping Speed 3.1 ls -1
Max. Inlet Pressure 2.5/3 m3h-1
Dimension Length 0.314 m
Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Supply Frequency 60 Hz
Dimension Height 0.456 m
Cooling Method Air Cooling (forced - fan)
Dimension Width 0.495 m
IP Rating IP40
Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Weight 88.2lb. (40.00 kg)
Electrical Requirements 115V AC,+/- 5% 60Hz, 1Ph

Manufacturer's List Price: $32,487.00
Our Price: $28,649.85
Sale Price: $26,995.00
Money Saved: $5,492.00
Edwards ELD500 DRY - 200-240V 50/60Hz  Helium Leak Detector Edwards ELD500 DRY - 200-240V 50/60Hz Helium Leak Detector

Lowest Detectable Helium Leak Rate Vacuum Operation ≤ 3 x 10 -11 mbar ls-1
Lowest Detectable Helium Leak Rate Sniffer Operation ≤ 7 x 10 -9 mbar ls-1
Maximum Measurable Helium Leak Rate > 0.1 mbar ls -1
Measurement Ranges 12 Decades
Time Constant for Leak Rate Signal < 1 Second
Helium Pumping Speed Fine Mode 3.1 ls -1
Inlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (forced - fan)
IP Rating IP40
Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Weight 78.3lb. (35.5 kg)
Electrical Requirements 200-240V AC, 50/60Hz, 1Ph

Manufacturer's List Price: $38,613.12
Our Price: $30,623.92
Money Saved: $7,989.20
Edwards ELD500 DRY, 100-120V, 60Hz  Helium Leak Detector Edwards ELD500 DRY, 100-120V, 60Hz Helium Leak Detector

Lowest Detectable Helium Leak Rate Vacuum Operation ≤ 3 x 10 -11 mbar ls-1
Lowest Detectable Helium Leak Rate Sniffer Operation ≤ 7 x 10 -9 mbar ls-1
Maximum Measurable Helium Leak Rate > 0.1 mbar ls -1
Measurement Ranges 12 Decades
Time Constant for Leak Rate Signal < 1 Second
Helium Pumping Speed Fine Mode 3.1 ls -1
Inlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (forced - fan)
IP Rating IP40
Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Weight 78.3lb. (35.5 kg)
Electrical Requirements 115V AC +/- 5%, 60Hz, 1Ph

Manufacturer's List Price: $38,613.12
Our Price: $28,885.80
Money Saved: $9,727.32
Edwards ELD500 - 200-240V 50/60Hz EU Helium Leak Detector Edwards ELD500 - 200-240V 50/60Hz EU Helium Leak Detector

Lowest Detectable Helium Leak Rate Vacuum Operation ≤ 5 x 10 -12 mbar ls-1
Lowest Detectable Helium Leak Rate Sniffer Operation ≤ 7 x 10 -9 mbar ls-1
Maximum Measurable Helium Leak Rate > 0.1 mbar ls -1
Measurement Ranges 12 Decades

Time Constant for Leak Rate Signal

< 1 Second
Helium Pumping Speed Fine Mode 3.1 ls -1
Inlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (forced - fan)
IP Rating IP40
Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Weight 88.2lb. (40.00 kg)
Electrical Requirements 200-240V AC, 50/60Hz, 1Ph

Manufacturer's List Price: $36,385.44
Our Price: $30,210.26
Money Saved: $6,175.18
Edwards ELD500 FLEX, 100-240V, 50/60Hz Helium Leak Detector Edwards ELD500 FLEX, 100-240V, 50/60Hz Helium Leak Detector

Lowest Detectable Helium Leak Rate Vacuum Operation ≤ 5 x 10 -12 mbar ls-1 (Backing Pump Dependent)
Lowest Detectable Helium Leak Rate Sniffer Operation ≤ 7 x 10 -9 mbar ls-1 (Sniffer Line and Ambient Conditions Dependent)
Maximum Measurable Helium Leak Rate > 0.1 mbar ls -1
Measurement Ranges 11 Decades
Time Constant for Leak Rate Signal < 1 Second
Helium Pumping Speed Fine Mode 3.1 ls -1
Inlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (forced - fan)
IP Rating IP40
Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Weight 66.1lb. (30.0 kg)
Electrical Requirements 100-240V AC, 50/60Hz, 1Ph

Manufacturer's List Price: $34,865.60
Our Price: $25,306.40
Money Saved: $9,559.20