Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 85L, 208/220/240V
Sterilization Temperature Range
105ºC to 135ºC
Chamber Dimensions
16.5 x 24.2 in(42 x 61.5 cm)
- Space-saving design with lid opening upward
- Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature
- Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C
- Agar melting mode for melting agar and maintaining it at liquid temperature, or for a hot, faster start-up
- One-touch lever to easily open and close chamber lid
- In-process display shows the status and the progress of sterilization cycle
- Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly
The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-containers, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of agar, media, wastes, glassware, and fermenters, especially for the larger models.
The Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 85L, 208/220/240V includes:
- Power Cord
- Operator's Manual
- 1 Year Manufacturer's Warranty
Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 85L, 208/220/240V Specifications
Temperature Operating Range
|
105ºC to 135ºC
|
Temperature Display Range
|
10ºC to 137ºC
|
Temperature Warming Range
|
45ºC to 60ºC
|
Temperature Agar Dissolution
|
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulations)
|
Gauge Pressure Operating Range
|
3 to 30 psi (0.021 to 0.206MPa)
|
Gauge Pressure Maximum Allowable
|
38 psi ( 0.26MPa)
|
Sterilization Timer
|
1 to 250 minutes
|
Delayed Auto-start Timer
|
Program autoclave to start 1 minute to 7 days later
|
Dimensions Overall (W x D x H)
|
26.0" x 25.6" x 39.4"
(66 cm x 65 cm x 100 cm)
|
Dimensions Chamber
(Diameter x Height)
|
85 liters
16.5" x 24.2" (42.0 cm x 61.5 cm)
|
Safety Devices
|
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
|
Programs for agar
|
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
|
Programs for liquids
|
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
|
Programs for solids
|
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
|
Programs for melting agar or for faster start-up
|
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
|
Power Source
|
208V/220V/240V, 50/60 Hz, single phase
|
Power Consumption
|
3000 watts (3000VA)
|
SHIPPING WEIGHT
|
282 lb (128 kg)
|
Specification |
HG-50 50L, 120V |
HG-80 85L, 208/220/240V |
HV-110 110L, 208/220/240V |
HV-25 25L, 120V |
HV-50 50L, 120V |
HV-85 85L, 208/220/240V |
HVA-110 110L, 208/220/240V |
HVA-85 85L, 208/220/240V |
HVE-50 50L, 120V |
HVP-50 50L, 120V |
Overall Dimensions (W x D x H) |
19.7" x 27.2" x 35.0" |
19.7" x 27.2" x 40.6" |
26.0" x 25.6" x 46.5" |
19.0" x 18.0" x 37.4" |
20" x 21" x 41" |
26.0" x 25.6" x 39.4" |
26.0" x 25.6" x 46.4" |
26.0" x 25.6" x 39.4" |
20.1" x 20.8" x 40.9" |
20.1" x 24.8" x 40.9" |
Chamber Size |
50L (14.3" x 19.0") |
76L (14.3" x 28.7") |
110L (16.5" x 31.3") |
25L (9.4" x 21.6") |
50L (11.8" x 28.0") |
85L (16.5" x 24.2") |
110L (16.5" x 31.3") |
85L (16.5" x 24.2") |
50L (11.8" x 28") |
50L (11.8" x 28") |
Temperature Range |
105°C to 135°C |
105°C to 135°C |
105°C to 135°C |
105°C to 126°C |
105°C to 135°C |
105°C to 135°C |
105°C to 135°C |
105°C to 135°C |
105°C to 135°C |
105°C to 135°C |
Sterilization Timer |
1 to 300 minutes |
1 to 300 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
Power Requirements |
120V or 220V |
220V |
208/220/240V |
120V |
120V |
208/220/240V |
208/220/240V |
208/220/240V |
120V |
120V |
Power Consumption |
2.0kW (3.0kW for 220V) |
3.8 kW |
4000 watts |
1500 watts |
2000 watts |
3000 watts |
4000 watts |
3000 watts |
2000 watts |
2000 watts |
Shipping Weight |
180 lb |
255 lb |
308 lb |
160 lb |
180 lb |
282 lb |
308 lb |
282 lb |
180 lb |
291 lb |
|
|
|
|
|
|
|