Accuris MR9620 SmartReader Multimode Microplate Reader w/ PC Software Included



Detection Modes
Absorbance, Fluorescence, Luminescence

Microplate Formats
6, 12, 24, 48, 96, and 384-well

Plate Incubation
Ambient +4°C to 45°C

Features
  • Intuitive, 10-inch color touch screen
  • Stand-alone system with optional PC software (FDA CFR Part 11)
  • Monochromator-based system for UV through visible absorbance
  • Filter module system for fluorescence assays
  • Advanced PMT detector for luminescence assays
  • Optional automatic injection modules for flash luminescence
  • 2 Year Manufacturer's Warranty
The Accuris SmartReader Multimode is an advanced microplate reader designed to meet the growing needs of advanced life science labs. Equipped with a full suite of high-performance optical systems, the SmartReader Multimode is your all-in-one solution for absorbance, fluorescence, and luminescence applications. The SmartReader Multimode quickly processes assays in standard 96 well plates and can also accept 6, 12, 24, 48 and 384 well plates. Programming and operation are managed from the instrument’s large color touch screen and no external computer or software is required. Optional PC software is available for easy control and data handling via a Windows™ PC. The friendly and intuitive interface guides the user through various options for assay set up and processing. The instrument features a built-in plate shaker with linear, orbital, and double-orbital shaking modes, and an incubator that can perform top heating from Ambient +4°C to 45°C. Top heating creates a temperature gradient to prevent condensation when lids are used on the microplates. Upon startup, the SmartReader Multimode performs a self-diagnostic test, followed by an automatic calibration of the entire system, ensuring consistent results across a wide range of assays.

Utilizing an advanced monochromator and a long-life, broad-spectrum xenon flash lamp, the SmartReader Multimode can produce incident light at user-selected wavelengths from 200 to 1000 nm in 1 nm steps. Processing assays is fast; a full 96 well plate can be read in under 15 seconds. The kinetic assay feature performs multiple readings over a set period, with curves for each well displayed in real-time. The optional SmartDrop plate allows fast and convenient UV absorbance evaluation of up to 16 nucleic acid and protein sample droplets. Absorbance applications include ELISA Assays, Colorimetric Assays (Bradford, Lowry, etc.), Enzyme Kinetics, Spectral Scanning, DNA & RNA Analysis, and more.

Three filter modules are included to provide the most common excitation and emission wavelengths needed for fluorescence assays. Additional filter modules are available. These advanced modules incorporate dichroic mirrors with narrow band-pass optical filters and ensure high light transmission, increased detection sensitivity, and are easily exchanged. Modules are barcoded for automatic loading of wavelength data. The SmartReader Multimode allows for automatic dynamic range selection, which allows for the gain of the photomultiplier tube to accurately capture and normalize the signal intensity of samples.

The SmartReader Multimode is capable of luminescent detection and can process both flash and glow assays. An advanced PMT (photo multiplier tube) enhances sensitivity of weak signals, prevents over-saturation of strong signals, and provides an ideal detection range for all common luminescence applications. Up to 2 sample injectors (available separately) can be installed and are compatible with both 96 and 384-well plates. Data from the SmartReader Multimode to can be exported as either a .XLS or .CSV file via the included USB flash drive, the FTP server, or by using the optional SmartReader PC Software. The SmartReader PC Software allows for remote programming & operation of the instrument via cable connection. Data from the instrument is automatically uploaded to the connected PC for further analyses. Both a Research version for academic use, and a FDA 21 CFR Part 11 compliant version are available.

INCLUDED:
The Accuris MR9620 SmartReader Multimode Microplate Reader includes:
  • Three Fluorescence Filter Cartridges (Excitation/Emission) 470/525nm, 523/564nm, & 624/692nm
  • PC Software
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 2 Year Manufacturer's Warranty

Accuris MR9620 SmartReader Multimode Microplate Reader Specifications

General Specifications
Measurement Technologies Absorbance, Fluorescence, Luminescence
Plate Formats 6- to 384-well plates
Shaking Linear (4.7 Hz, 7.0 Hz, 13.5 Hz), orbital and double orbital (240 – 1200 rpm)
Incubation Range RT +4 °C to 45 °C
Display 10.0 inch touchscreen
Communication Ports 2 USB A type ports / 1 USB B type port

1 Ethernet port

RS232 interface

Dimensions (WxDxH) 16.5 x 21.7 x 15.2 in.

(42.0 x 55.0 x 38.6 cm)

Power Input AC 100 to 240 V, 50 to 60 Hz
Weight 33 kg / 72.8 lbs
Absorbance Specifications
Light Source High Energy Xenon Flash Lamp
Detector Photodiode
Wavelength Accuracy 2 nm
Wavelength Repeatability 0.2 nm
Bandwidth (FWHM) > 2.5 nm
Wavelength Range 200 – 1000 nm, 1nm steps
Absorbance 0.0 – 4.0 OD
Resolution 0.0001 OD
Accuracy 96-precision mode:± (1.0 %+0.003Abs)@ (0.0-2.0Abs] ;± 2.0 % @ (2.0-3.0Abs]
Repeatability CV < 1.0 % or SD< 0.003 Fast(0.0-3.0Abs]CV < 0.5 % or SD< 0.003 Accurate(0.0-3.0Abs]
Stray Light 0.1 % @ 220 nm
Linearity R2 > 0.999 @ [0.0-3.0Abs]
Measurement Speed < 15 seconds
Fluorescence Specifications
Reading Mode Top Reading
Excitation Light Source High Energy Xenon Flash Lamp
Detector Photo Multiplier Tube (PMT)
Detection Limit ≤ 1 pM
Wavelength Range EX: 200 – 1000 nm; EM: 270 – 850 nm
Included Filter Cartridges (EX / EM): 470 / 525nm ; 523 / 564nm ; 624 / 692nm
Linear Dynamic Range 6 logs
Luminescence Specifications
Detector Photo Multiplier Tube (PMT)
Detection Limit 15 amol / well
Linear Dynamic Range 6 logs

Comparison of Models

Spec / Product Accuris MR9600 SmartReader 96 Accuris MR9600-T SmartReader 96 Accuris MR9610 SmartReader Accuris MR9611 SmartReader Accuris MR9620 SmartReader
Measurement Technologies Absorbance Absorbance Absorbance Absorbance Absorbance, Fluorescence, Luminescence
Wavelength Range 340 to 750 nm (405, 450, 492, and 630 nm filters included) 340 to 750nm (405, 450, 492) and 630 nm filters included) 200 to 1000 nm with 1 nm steps 200 to 1000nm 200 to 1000 nm, 1nm steps
Plate Format 96-Well Plates 96-Well Plates 96-well and 384-well flat bottom 96-well and 384-well flat bottom (cuvettes accepted in MR9611 model) 6- to 384-well plates
Test Speed < 6 sec. for 96 well plate <6 sec. for 96 well plate 96 well plate: <8 seconds (fast mode); 384 well plate: <74 seconds 96 well plate: <6 seconds (fast mode); 384 well plate: <74 seconds < 15 seconds
Shaking 3 modes: slow, medium, fast 3 modes: slow, medium, fast Linear; three options: (16.8Hz, 1mm), (6.68Hz, 3mm), (2.44Hz, 15mm) Linear; three levels of shaking speed Linear (4.7 Hz, 7.0 Hz, 13.5 Hz), orbital and double orbital (240 – 1200 rpm)
Incubation From ambient +5°C to 50°C From ambient + 5℃ to 45℃ From ambient + 5℃ to 45℃ From Ambient +5°C to 45°C RT +4 °C to 45 °C
Light Source Quartz-halogen lamp 6V/10W Quartz-halogen lamp 6V/10W Xenon Flash Lamp Xenon Flash Lamp High Energy Xenon Flash Lamp
Downloads


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Microplate Readers
Brands
Brands > Accuris
Microplate Reader Wavelength Range
Microplate Reader Wavelength Range > 200 to 1,000 nm
Microplate Reader Detection Methods
Microplate Reader Detection Methods > Absorbance (Uv-Vis)
Microplate Reader Detection Methods > Luminescence
Microplate Reader Detection Methods > Fluorescence