Hirayama HICLAVE HVE-50 Economical Floor-Standing Autoclave, 50L, 120V Hirayama HICLAVE HVE-50 Economical Floor-Standing Autoclave, 50L, 120V

Temperature Operating Range 105ºC to 135ºC
Temperature Display Range 5ºC to 137ºC
Temperature Warming Range 45ºC to 60ºC
Pressure Operating Range (gauge) 3 to 30 psi (0.021 to 0.206MPa)
Maximum Allowable Pressure 38 psi ( 0.26MPa)
Sterilization Timer 1 to 250 minutes
Overall Dimensions (W x D x H) 20.1" x 20.8" x 40.9" (51 cm x 53 cm x 104 cm)
Chamber Dimensions
(Diameter x Height)
50 liters
11.8" x 28" (30 cm x 71 cm)
Safety Devices Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for Agar/Liquids. Also for Melting Agar, or for Faster Start-Up Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion
Programs for Liquids/Solids Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion
Programs for Solids Heating -> Sterilization -> Auto exhaust (fast) -> Completion
Power Source 120V, 50/60 Hz, single phase (220V available on request)
Power Consumption 2000 watts (2000 VA)
Weight 180 lb (82 kg)

Manufacturer's List Price: $11,850.00
Our Price: $10,465.00
Money Saved: $1,385.00
Hirayama HICLAVE HV-25 Floor-Standing Autoclave, 25L, 120V Hirayama HICLAVE HV-25 Floor-Standing Autoclave, 25L, 120V

Temperature Operating Range
105ºC to 126ºC
Temperature Display Range
128ºC
Temperature Warming Range
45ºC to 60ºC
Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulation)
Operating Range
3 to 22 psi gauge (0.02 to 148MPa)
Maximum Allowable Pressure
27 psi (0.186MPa)
Sterilization Timer
1 to 250 minutes
Delayed Auto-start
Program autoclave to start 1 minute to 7 days later
Overall Dimensions (W x D x H)
19.0" x 18.0" x 37.4"
(48 cm x 46 cm x 95 cm)
Chamber DImensions
(Diameter x Height)
25 liters
9.4" x 21.6" (24 cm x 55 cm)
SAFETY DEVICES
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
Programs for liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
Programs for solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
Programs for melting agar or for faster start-up
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
Power Source
120V, 50/60 Hz (220V/240V available)
Power Consumption
1500 watts (1500VA)
SHIPPING WEIGHT
160 lb (73 kg)

Manufacturer's List Price: $9,950.00
Our Price: $8,955.00
Money Saved: $995.00
Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 85L, 208/220/240V Hirayama HICLAVE HV-85 Floor-Standing Autoclave, 85L, 208/220/240V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
10ºC to 137ºC
Temperature Warming Range
45ºC to 60ºC
Temperature Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulations)
Gauge Pressure Operating Range
3 to 30 psi (0.021 to 0.206MPa)
Gauge Pressure Maximum Allowable
38 psi ( 0.26MPa)
Sterilization Timer
1 to 250 minutes
Delayed Auto-start Timer
Program autoclave to start 1 minute to 7 days later
Dimensions Overall (W x D x H)
26.0" x 25.6" x 39.4"
(66 cm x 65 cm x 100 cm)
Dimensions Chamber
(Diameter x Height)
85 liters
16.5" x 24.2" (42.0 cm x 61.5 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
Programs for liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
Programs for solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
Programs for melting agar or for faster start-up
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
Power Source
208V/220V/240V, 50/60 Hz, single phase
Power Consumption
3000 watts (3000VA)
SHIPPING WEIGHT
282 lb (128 kg)

Manufacturer's List Price: $17,900.00
Our Price: $16,110.00
Money Saved: $1,790.00
Hirayama HICLAVE HV-110 Floor-Standing Autoclave, 110L, 208/220/240V Hirayama HICLAVE HV-110 Floor-Standing Autoclave, 110L, 208/220/240V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
10ºC to 137ºC
Temperature Warming Range
45ºC to 60ºC
Temperature Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulations)
Gauge Pressure Operating Range
3 to 30 psi (0.021 to 0.206MPa)
Gauge Pressure Maximum Allowable
38 psi ( 0.26MPa)
Sterilization Timer
1 to 250 minutes
Delayed Auto-start Timer
Program autoclave to start 1 minute to 7 days later
Dimensions Overall (W x D x H)
26.0" x 25.6" x 46.5"
(66 cm x 65 cm x 118 cm)
Dimensions Chamber
(Diameter x Height)
110 liters
16.5" x 31.3" (42.0 cm x 79.5 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
Programs for liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
Programs for solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
Programs for melting agar or for faster start-up
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
Power Source
208V/220V/240V, 50/60 Hz, single phase
Power Consumption
4000 watts (4000VA)
SHIPPING WEIGHT
308 lb (140 kg)

Manufacturer's List Price: $20,500.00
Our Price: $18,450.00
Money Saved: $2,050.00
Hirayama HICLAVE HG-80 Floor-Standing Autoclave with Automatic Lid, 85L, 208/220/240V Hirayama HICLAVE HG-80 Floor-Standing Autoclave with Automatic Lid, 85L, 208/220/240V

Overall (W x D x H)
19.7" x 27.2" x 40.6"
(45.5 cm x 69.1 cm x 103.0 cm)
Chamber
(Diameter x Height)
76 liters
14.3" x 28.7" (36.4 cm x 73.0 cm)
Temperature Range
105°C to 135°C
Sterilization Timer
1 to 300 minutes
Agar Warming Range
After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start
Program autoclave to start 1 to 99 hours later
Cooling Fan
Switch to turn fan on or off
Air Removal Timer
Programmable, 3 to 9 minutes after temperature has reached 97°C
Steam Venting
Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock
Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles
1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution
Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol
Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.
Safety Features
Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser
15-liter water tank
Drain Water Bottle
2 liters
Power Requirements
220V, 50/60 Hz, single phase
Power Consumption
3.8 kW
Shipping Weight
255 lb (116 kg)

Manufacturer's List Price: $18,200.00
Our Price: $16,380.00
Money Saved: $1,820.00
Hirayama HICLAVE HVA-85 Economical Floor-Standing Autoclave with Cooling Fan, 85L, 208/220/240V Hirayama HICLAVE HVA-85 Economical Floor-Standing Autoclave with Cooling Fan, 85L, 208/220/240V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
137ºC
Temperature Agar Warming Range
After sterilization, agar can be maintained from 45ºC to 60ºC
(programmable) to prevent coagulation for up to 20 hours.
Maximum Allowable Pressure
38 psi (0.26MPa)
Pressure Operating Range (gauge)
3 to 30 psi (0.021 to 0.206MPa)
Sterilization Timer
1 to 250 minutes
Overall Dimensions (W x D x H)
26.0"" x 25.6" x 39.4"
(66 cm x 65 cm x 100 cm)
Chamber Dimensions
(Diameter x Height)
85 liters
16.5" x 24.2" (42.0 cm x 61.5 cm)
SAFETY DEVICES
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for Agar
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion
Programs for Liquids
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion
Programs for Solids
Heating -> Sterilization -> Auto exhaust (fast) -> Completion
Power Source
208V / 220V / 240V, 50 / 60 Hz, single phase
Power Consumption
3000 watts (3000VA)
SHIPPING WEIGHT
282 lb (128 kg)

Manufacturer's List Price: $16,800.00
Our Price: $15,120.00
Money Saved: $1,680.00
Hirayama HICLAVE HVA-110 Economical Floor-Standing Autoclave with Cooling Fan, 110L, 208/220/240V Hirayama HICLAVE HVA-110 Economical Floor-Standing Autoclave with Cooling Fan, 110L, 208/220/240V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
137ºC
Agar Warming Range
After sterilization, agar can be maintained from 45ºC to 60ºC
(programmable) to prevent coagulation for up to 20 hours.
Maximum Allowable Pressure
38 psi (0.26MPa)
Pressure Operating Range (gauge)
3 to 30 psi (0.021 to 0.206MPa)
Sterilization Timer
1 to 250 minutes
Overall Dimensions (W x D x H)
26.0" x 25.6" x 46.4" in
(66 cm x 65 cm x 118cm)
Chamber Dimensions
(Diameter x Height)
110 liters
16.5" x 31.3" (42.0 cm x 79.5 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for Agar
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion
Programs for Liquids
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion
Programs for Solids
Heating -> Sterilization -> Auto exhaust (fast) -> Completion
Power Source
208V / 220V / 240V, 50 / 60 Hz, single phase
Power Consumption
4000 watts (4000VA)
Shipping Weight
308 lb (140 kg)

Manufacturer's List Price: $19,200.00
Our Price: $17,280.00
Money Saved: $1,920.00
Hirayama HICLAVE HVP-50 Floor-Standing Autoclave with Heat/Vacuum Drying, 50L, 120V Hirayama HICLAVE HVP-50 Floor-Standing Autoclave with Heat/Vacuum Drying, 50L, 120V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
5ºC to 140ºC
Pressure Operating Range (gauge)
3 to 28.4 psi (0.2 to 2.0 kg/cm² )
Sterilization Timer
1 to 250 minutes
Drying Timer
1 to 90 minutes
Overall Dimensions (W x D x H)
20.1" x 24.8" x 40.9" (51 x 63 x 104) cm
Chamber Dimensions
(Diameter x Height)
50 liter
11.8" x 28" (30 cm x 71 cm)
Safety Devices
Temperature- and pressure-sensitive lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, lid-closure detector, over-current detector and circuit breaker with ground fault circuit interrupter.
Programs for Solids with Drying
Heating and air removal from chamber by vacuum pump (pre-vac) -> Sterilization -> Water and steam exhaust (fast) -> Drying by heat and vacuum -> Completion
Programs for Wastes/Solids without Drying
Heating -> Pre-vac -> Sterilization -> Steam exhaust (fast) -> Completion
Programs for Liquids/Agar
Heating -> Sterilization -> Auto steam exhaust (programmable rates, or ambient cooling w/o steam exhaust) -> Completion
Programs for Drying without Sterilization
Drying with heat and vacuum (time programmable) -> Completion(for additional drying after Program #1, if desired)
Power Source
120V, 50/60 Hz, single phase (220V/240V available on request)
Power Consumption
2000 watts (2000 VA)
Shipping Weight
291 lb (133 kg)

Manufacturer's List Price: $20,950.00
Our Price: $18,855.00
Money Saved: $2,095.00
Hirayama HICLAVE HV-50 Floor-Standing Autoclave, 50L, 120V Hirayama HICLAVE HV-50 Floor-Standing Autoclave, 50L, 120V

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
137ºC
Temperautre Warming Range
45ºC to 60ºC
Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulation)
Pressure Operating Range (gauge)
3 to 30 psi (0.02 to 0.206MPa)
Maximum Allowable Pressure
38 psi (0.26MPa)
Sterilization Timer
1 to 250 minutes
Delayed Auto-start Timer
Program autoclave to start 1 minute to 7 days later
Overall Dimensions (W x D x H)
20" x 21" x 41"
(51 cm x 53 cm x 104 cm)
Chamber Dimensions
(Diameter x Height)
50 liters
11.8" x 28.0" (30 cm x 71 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
Programs for liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
Programs for solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
Programs for melting agar or for faster start-up
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
Power source
120V, 50/60 Hz (220V/240V available)
Power consumption
2000 watts (2000VA)
SHIPPING WEIGHT
180 lb (82 kg)

Manufacturer's List Price: $12,700.00
Our Price: $11,430.00
Money Saved: $1,270.00
Hirayama HICLAVE HG-50 Floor-Standing Autoclave with Automatic Lid, 50L, 120V Hirayama HICLAVE HG-50 Floor-Standing Autoclave with Automatic Lid, 50L, 120V

Overall (W x D x H)
19.7" x 27.2" x 35.0"
(45.5 cm x 69.1 cm x 89.0 cm)
Chamber Dimensions
(Diameter x Height)
50 liters
14.3" x 19.0" (36.4 cm x 48.2 cm)
Temperature Range
105°C to 135°C
Sterilization Timer
1 to 300 minutes
Agar Warming Range
After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start
Program autoclave to start 1 to 99 hours later
Cooling Fan
Switch to turn fan on or off
Air Removal Timer
Programmable, 3 to 9 minutes after temperature has reached 97°C
Steam Venting
Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock
Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles
1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution
Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol
Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.
Safety Features
Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser
15-liter water tank
Drain Water Bottle
2 liters
Power Requirements
120V or 220V, 50/60 Hz, single phase
Power Consumption
2.0kW, optional 3.0kW for 220V only
Shipping Weight
180 lb (82 kg)

Manufacturer's List Price: $13,200.00
Our Price: $11,880.00
Money Saved: $1,320.00