IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling
Measuring Range Max.
40000 J
Measuring Time Dynamic Approx.
8 min
Cooling Medium Permissable Operating Pressure
2 bar
- Compact, space-saving, and cost-effective design for educational and low-volume industrial laboratories
- Capable of measuring calorific values for liquid and solid samples
- Four operation modes: isoperibol, dynamic, manual, and time-controlled (14 min).
- Semi-automated system with manual water and oxygen handling, and optional automation available
- Closed-loop water circulation with optional RC 2 basic chiller for improved reproducibility and efficiency
- Includes C 5012 decomposition vessel, suitable for high-halogen and sulfur samples (> 3%)
- Operated via C 6040 CalWin software for monitoring, multi-calorimeter management, and data export
- Compatible with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711, GOST 147, GOST 21261
- Compact dimensions (15.7 x 15.7 x 15.7 in.) and lightweight (46.3 lb.) for ease of installation
- Installation and calibration consumables included for seamless setup
The IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results.
The semi-automated and conforming-to-standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses.
The catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and/or sulfur is required after the combustion.
Four different operation modes enable the user to control the measuring times according to individual requirements:
Isoperibol: approx: 17 min.
Dynamic : approx. 8 min
Manual : approx. 17 min (depends on the operator)
Time controlled : 14 min
Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately.
The IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling
includes:
- C 5012 Decomposition Vessel, Halogen Resistant
- C 200.2 Conversion Kit for C 5012
- C 200.RC Set of Hoses
- RC 2 Basic Recirculating Chiller
- C 248 Oxygen Filling Station
- Ignation Adapter
- Water Emptying Hose
- Operator's Guide
- Manufacturer's Documentation
- 1 Year Manufacturer's Warranty ( + Additional Free 1 Year Warranty Extension with IKA Registration)
IKA C 200 h auto Semi-Automated Halogen Resistant Calorimeter w/ Automated Water Handling
Specifications
Measuring Range Max.
|
40000 J
|
Measuring Mode Dynamic 25°C
|
Yes
|
Measuring Mode Isoperibol 25°C
|
Yes
|
Measuring Time Dynamic Approx.
|
8 Min
|
Measuring Time Isoperibol Approx.
|
17 Min
|
Reproducibility Dynamic (1g Benzoic Acid NBS39i)
|
0.1% RSD
|
Reproducibility Isoperibol (1g Benzoic Acid NBS39i)
|
0.1% RSD
|
Working Temperature Max.
|
25 °C
|
Temperature Measurement Resolution
|
0.0001 K
|
Cooling Medium Permissible Operating Pressure
|
2 Bar
|
Cooling Medium
|
Tap Water
|
Type of Cooling
|
Flow
|
Chiller
|
RC 2 Basic
|
Rec. Flow Rate at 18°C
|
60 L/H
|
Oxygen Operating Pressure Max.
|
40 Bar
|
Interface Printer
|
Centronix
|
Interface PC
|
RS232
|
Decomposition Vessel C 5010
|
Yes
|
Works According to DIN 51900
|
Yes
|
Works According to DIN EN ISO 1716
|
Yes
|
Works According to DIN EN ISO 18125
|
Yes
|
Works According to DIN EN 15400
|
Yes
|
Works According to DIN CEN TS 14918
|
Yes
|
Works According to DIN CEN/TS 16023
|
Yes
|
Works According to DIN SPEC 19524
|
Yes
|
Works According to ASTM D240
|
Yes
|
Works According to ASTM D4809
|
Yes
|
Works According to ASTM D5468
|
Yes
|
Works According to ASTM D5865
|
Yes
|
Works According to ISO 1928
|
Yes
|
Works According to GOST Certified
|
Yes
|
Permissible Ambient Temperature
|
20 to 25°C
|
Permissible Relative Humidity
|
80 %
|
Protection Class According to DIN EN 60529
|
IP 20
|
RS 232 Interface
|
Yes
|
Dimensions (W x H x D)
|
15.7 x 15.7 x 15.7 in. (40 x 40 x 40 cm)
|
Weight
|
46.3 lb. (21 kg)
|
Electrical Requirements
|
100 to 240 V 50/60 Hz, 120 W
|
|
|
|
|
|
|
|