Accuris SmartDrop XF Nano Spectrophotometer, 115V
Wavelength Range
200 - 800nm (1 nm steps)
Display
7-inch High Resolution Color Touch Screen
Absorbance Precision
0.003A
- 7-inch touch screen display
- 0.5µl – 2.0µl minimum sample size
- Detects dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein
- Full-spectrum absorbance scanning and calculations of 260/280 and 260/230 ratios
- Long-life Xenon lamp with precision monochromator
- Auto-ranging path lengths of 0.05mm, 0.2mm and 1.0mm
- Detect up to 15,000ng/µl of dsDNA without dilution
- Integrated fluorometer for sensitive quantitation of low concentration nucleic acids
- < 6 second detection time
This top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.
The integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon request.
Click Here to View Product Video
The Accuris SmartDrop XF Nano Spectrophotometer, 115V includes:
- Power Cord
- Operator's Guide
- Manufacturer's Documentation
- 1 Year Manufacturer's Warranty
Accuris SmartDrop XF Nano Spectrophotometer, 115V Specifications
Model
|
SmartDrop XF (NS1020)
|
Display
|
7-inch touch screen
|
Minimum sample size
|
0.5µl – 2.0µl
|
Path length
|
0.05mm, 0.2mm, 1.0mm
|
Light source
|
Xenon Flash Lamp
|
Detector
|
2048 Element Linear Silicon CCD Array
|
Wavelength
|
200 – 800nm (1nm steps)
|
Absorbance range
|
0.04 – 300 A (10mm equivalent)
|
Absorbance precision
|
0.003 A
|
Lower limit of detection
|
dsDNA: 2ng/µl ; BSA: 0.1mg/ml
|
Upper limit of detection
|
dsDNA: 15,000ng/µl; BSA: 360mg/ml
|
Detection time
|
< 6 seconds
|
Communication ports
|
USB for data export
|
Voltage input
|
DC 24V, 2A
|
Power
|
25W
|
Dimensions (WxDxH)
|
20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
|
Weight
|
3.6 kg / 7.9 lbs
|
Cuvette OD600 detection
|
Absorbance range
|
0.0 – 4.0 A
|
Absorbance stability
|
[0,3) ≤ 0.5%, [3,4) ≤ 2%
|
Absorbance repeatibility
|
[0,3) ≤ 0.5%, [3,4) ≤ 2%
|
Absorbance precision
|
[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%
|
Fluorescence detection
|
Excitation/Emission
|
460 ± 20nm / 525-570nm
|
Sensitivity
|
dsDNA: 0.5pg/µl
|
Linearity
|
R² ≥ 0.995
|
Repeatibility
|
≤ 1.5%
|
Stability
|
≤ 1.5%
|
Spec / Product | Accuris SmartDrop L Nano Spectr | Accuris SmartDrop X Nano Spectr | Accuris SmartDrop XF Nano Spect | Wavelength | 260, 280, & 600nm | 200 – 800nm (1nm steps) | 200 – 800nm (1nm steps) | Absorbance Range | 0.2 – 50 A (10mm equivalent) | 0.04 – 90 A (10mm equivalent) | 0.04 – 300 A (10mm equivalent) | Absorbance Precision | 0.005 A | 0.003 A | 0.003 A | Absorbance Stability | [0,3) ≤ 0.5%, [3,4) ≤ 2% | [0,3) ≤ 0.5%, [3,4) ≤ 2% | [0,3) ≤ 0.5%, [3,4) ≤ 2% | Detector | UV Silicon Photocell | 2048 Element Linear Silicon CCD Array | 2048 Element Linear Silicon CCD Array | Light Source | UV LED | Xenon Flash Lamp | Xenon Flash Lamp |
|
|
|
|
|
|
|