MARSHALL Select MS-PA100UL Autoclavable Pipette, 10-100ul
Pipette Type
Manual Air Displacement
- Covers 10 to 100 ul for versatile applications
- 1 µl increments for precise volume adjustments
- Lightweight and low-force design reduces hand strain
- Quick-release pipette tip ejector for easy tip changes
- Made from innovative materials for long-lasting use
- Serializable at 121°C without special preparation
- Works with universal pipette tips for added flexibility
The MARSHALL Select MS-PA100UL Autoclavable Pipette is a precision instrument designed for a wide range of laboratory applications, offering a volume range of 10 to 100 µl with 1 µl increments for precise volume control. This pipette delivers systematic error rates of 3% at 10 µl, 1% at 50 µl, and 0.8% at 100 µl, along with random error rates of 1.5% at 10 µl, 0.4% at 50 µl, and 0.15% at 100 µl, ensuring high accuracy and reliability for various tasks. The lightweight, ergonomic design reduces hand strain and minimizes the risk of repetitive strain injuries, making it comfortable for extended use. A centrally located digital display ensures easy readability for both left- and right-handed users, enhancing usability. The rotating counter knob allows for quick volume adjustments, while the quick-release pipette tip ejector facilitates convenient tip changes. Constructed from innovative materials, the pipette is easy to calibrate and maintain, ensuring consistent performance over time.
Fully autoclavable at 121°C, the MS-PA100UL allows for thorough sterilization without special preparation, maintaining sterility and performance. After autoclaving, it can be cooled and dried over 12 hours, ready for immediate reuse. The pipette features a volume lock to prevent accidental adjustments and is compatible with universal pipette tips, supporting both forward and reverse pipetting techniques. This versatility makes it suitable for handling a wide range of sample viscosities, from low-viscosity liquids to higher-viscosity or foamy samples. As part of a comprehensive range covering volumes from 0.1 µl to 10 ml, the MS-PA100UL provides flexibility across diverse applications. With its robust construction and user-friendly features, this pipette is an indispensable tool for laboratories seeking precision and efficiency in liquid handling.
The
MARSHALL Select MS-PA100UL Autoclavable Pipette, 10-100ul includes:
- Operator's Guide
- Manufacturer's Documentation
- 1 Year Manufacturer's Warranty
MARSHALL Select MS-PA100UL Autoclavable Pipette, 10-100ul Specifications
Volume Range
|
10 to 100ul
|
Pipette Type
|
Manual Air Displacement
|
Adjustable or Fixed Volume
|
Adjustable
|
Volume Increments
|
1ul
|
Systematic Error (ul)
|
0.3 at 10ul
0.5 at 50ul
0.8 at 100ul
|
Systematic Error (%)
|
3% at 10ul
1% at 50ul
0.8% at 100ul
|
Random Error (ul)
|
0.15 at 10ul
0.2 at 50ul
0.1 at 100ul
|
Systematic Error (%)
|
1.5% at 10ul
0.4% at 50ul
0.15% at 100ul
|