Home > Vacuum Pump Accessories
Sort By:
Page of 4
Scilogex SCI100VC Benchtop Vacuum Controller, 100-230V Scilogex SCI100VC Benchtop Vacuum Controller, 100-230V

Vacuum Range 1 to 1000 mbar
Control Operation Mode Single-point control operation mode, program operation mode
Programmable Up to 5 programs with five-step control
Display Screen 5-inch TFT touch screen
Sensor Overload Pressure 1500 mbar
Tube Connection Interface Diameter 6.2mm
Materials in Contact with Steam PTFE, PP, Silica Gel, and Ceramics
Steam Temperature 5C to 40C
Input Power 600W
Output Power 300W (110V), 500W (220V)
Ambient Operating Conditions 10C to 40C, ≤ 80% RH
Dimensions (D x W x H) 18.9 x 20.7 x 19.3 cm
Weight 9 lb. (4.1 kg)
Electrical Requirements 110V to 240V, 50/60Hz

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $2,502.50
Our Price: $1,858.11
Money Saved: $644.39
Scilogex 400 Vacuum Regulator/Moisture Trap Scilogex 400 Vacuum Regulator/Moisture Trap

Vacuum Range 25 to 760mmHg (0.1 to 1 bar)
Materials PVDF, PTFE, ABS, Borosilicate Glass, Stainless Steel

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $476.44
Our Price: $353.76
Money Saved: $122.68
VACUUBRAND VACUU-VIEW Vacuum Gauge VACUUBRAND VACUU-VIEW Vacuum Gauge

Upper measuring limit in mbar/hPa 1100 mbar
Upper measuring limit in torr 825 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.075 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
ATEX conformity II 3/- G Ex h IIC T4 Gc X Internal Atm. only
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 and hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Venting valve No
Protection class IEC 60529 IP 54
Protection class UL50E Type 5
Protection class front side IEC 60529 IP 54
Weight 0.19 kg
Dimension L in mm 50 mm
Dimension B in mm 62 mm
Dimension H in mm 103 mm
Vacuum sensor Integr.
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with integrated vacuum sensor, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual.

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $1,660.00
Our Price: $1,494.00
Money Saved: $166.00
KNF VC 900 Vacuum Controller, 100-240V KNF VC 900 Vacuum Controller, 100-240V

Measurement Range 0 to 1100 mbar
Measurement Accuracy ± 1 mbar
Interface Mini-USB
Housing Materials Plastic
Protection Class IP30
Hose Connections

For Gas In: ID 10, PVDF

For Gas Out: ID 10, PVDF

For Venting: ID 4, nickel-plated brass

Permissible Ambient Temperature 10°C to 40°C
Operating Unit Dimensions (W x H x D) 3.9 x 7.1 x 2.6 in. (10.1 x 18.1 x 6.7 cm)
Control Unit Dimensions (W x H x D) 6.1 x 4.2 x 2.3 in.(15.5 x 10.9 x 6 cm)
Weight 2.6 lb. (1.2 kg)
Electrical Requirements 100-240V, 50/60Hz, 34W

Manufacturer's List Price: $4,659.00
Our Price: $3,785.44
Money Saved: $873.56
VACUUBRAND VACUU-VIEW Extended Vacuum Gauge VACUUBRAND VACUU-VIEW Extended Vacuum Gauge

Upper measuring limit in mbar/hPa 1100 mbar
Upper measuring limit in torr 825 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Ceramic diaphragm sensor + ceramic jacketed Pirani sensor
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar / +-3 mbar for > 5 mbar mbar/hPa/torr
ATEX conformity II 3/- G Ex h IIC T4 Gc X Internal Atm. only
Temperature coefficient +- 0.2 mbar/hPa/0.15 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 and hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Venting valve No
Protection class IEC 60529 IP 54
Protection class UL50E Type 5
Protection class front side IEC 60529 IP 54
Weight 0.19 kg
Dimension L in mm 50 mm
Dimension B in mm 62 mm
Dimension H in mm 103 mm
Vacuum sensor Integr.
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with integrated vacuum sensors, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual.

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $1,910.00
Our Price: $1,719.00
Money Saved: $191.00
VACUUBRAND DCP 3000 Vacuum Gauge with VSK 3000 Head VACUUBRAND DCP 3000 Vacuum Gauge with VSK 3000 Head

Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Weight 0.44 kg
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 114 mm
Vacuum sensor VSK 3000
Cable length of vacuum sensor 2 m
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with external vacuum sensor VSK 3000, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual.
Interface RS 232C

Manufacturer's List Price: $2,540.00
Our Price: $2,286.00
Money Saved: $254.00
VACUUBRAND VACUU-LAN Mini-Network VACUUBRAND VACUU-LAN Mini-Network

For Use With: Diaphragm Vacuum Pumps
Number of Lan Ports: 3

Usually Ships in 24 to 72 Hours
Manufacturer's List Price: $1,890.00
Our Price: $1,701.00
Money Saved: $189.00